Products Found: 155

Showing Results For: Current Transformers

Current Transformers

Current transformers (CTs) are indispensable components in modern-day electrical systems, widely used to ensure safe, accurate, and efficient measurement of electrical current. By stepping down high current levels to lower, manageable values, CTs enable precise monitoring, control, and protection of electrical equipment. Additionally, they provide the foundation for dependable electrical measurements, helping businesses maintain compliance, efficiency, and operational continuity.

What Makes Current Transformers Valuable?

Current transformers provide a safe and effective means of measuring high electrical currents without directly exposing instruments or personnel to high-voltage systems. Moreover, they allow precise readings, which is essential for monitoring energy usage, diagnosing issues, and optimising performance. Using CTs ensures compliance with regulations, enhances system reliability, and improves the overall safety of electrical infrastructure.

Crucial Features of Current Transformers

  • Ensure safety by isolating measuring instruments from high-voltage circuits.
  • Deliver accurate current measurements for energy efficiency and load management.
  • Aid in fault detection, helping to maintain system reliability and prevent costly downtime.

Popular Types Include

  • Bar-Type CTs: Designed for higher currents, often used in industrial applications.
  • Window-Type CTs: Versatile and easy to install, suitable for general-purpose use.
  • Split-Core CTs: Allow retrofitting without disconnecting existing conductors.

What are the Potential Benefits of Current Transformers?

  • High accuracy for reliable data collection.
  • Compact, durable designs suitable for various environments.
  • Wide range of current ratings and configurations.
  • Enhance safety and prevent damage to equipment.
  • Support compliance with industry standards.
  • Improve efficiency by allowing for real-time monitoring and control.

Application Information

  • Energy Metering: Accurate current measurement for billing and efficiency audits.
  • Power Distribution Systems: Monitoring and controlling electrical loads in substations.
  • Protection Systems: Safeguarding transformers, breakers, and motors from overcurrent conditions.
  • Industrial Facilities: Supporting process optimisation and reducing energy costs.
  • Renewable Energy Installations: Ensuring stable operation of solar and wind power systems.
Showing 1 -
Halltronics #
Manufacturer Part No
Name
Availability
Price
 
ZMCT206-1500 - CURRENT TRANSFORMER 10A
3985 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 0.51
900 +
£ 0.44
1 +
£ 0.51
VT1211-RC - VOLTAGE TRANSFORMER 1:1
49 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 10.08
10 +
£ 9.42
1 +
£ 10.08
VT1090-RC - VOLTAGE TRANSFORMER 110 Vrms 1:1
97 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 12.19
10 +
£ 11.39
1 +
£ 12.19
LA 200-P - TRANSDUCER CURRENT 200A HALL EFFECT,CLOSED LOOP
Obsolete
Check Stock & Lead Times Packaging Options
CKSR 50-NP - TRANSDUCER CURRENT 50A FLUX GATE,CLOSED LOOP
Obsolete
Check Stock & Lead Times Packaging Options
LES 25-NP - TRANSDUCER CURRENT 25A HALL EFFECT,CLOSE LOOP
Obsolete
Check Stock & Lead Times Packaging Options
LES 6-NP - TRANSDUCER CURRENT 6A HALL EFFECT,CLOSE LOOP
Obsolete
Check Stock & Lead Times Packaging Options
PREMO HCT-200LP, TRANSDUCER CURRENT 200A HALL EFFECT
Obsolete
Check Stock & Lead Times Packaging Options
LEM CAS 50-NP, TRANSDUCER CURRENT 50A FLUX GATE, CLOSED LOOP
Obsolete
Check Stock & Lead Times Packaging Options
LEM LF 2005-S, TRANSDUCER CURRENT 2000A HALL EFFECT,CLOSED LOOP
Obsolete
Check Stock & Lead Times Packaging Options
HMSR 30-SMS - IC-HMSR30 TRANSDUCER CURRENT 30A 5VDC 16PowerSOIC
Obsolete
Check Stock & Lead Times Packaging Options
LEM LF 505-S, TRANSDUCER CURRENT 500A HALL EFFECT,CLOSED LOOP
Obsolete
Check Stock & Lead Times Packaging Options
HCT-100AP - TRANSDUCER CURRENT 100A HALL EFFECT
Obsolete
Check Stock & Lead Times Packaging Options
LEM LTS 15-NP, TRANSDUCER CURRENT 15A HALL EFFECT, CLOSED LOOP
Obsolete
Check Stock & Lead Times Packaging Options
LEM HC2F-80-S, TRANSDUCER CURRENT 80A HALL EFFECT,OPEN LOOP,AUTO
Obsolete
Check Stock & Lead Times Packaging Options
LEM HLSR 20-P, TRANSDUCER CURRENT 20A HALL EFFECT,OPEN LOOP
Obsolete
Check Stock & Lead Times Packaging Options
LAS 50-TP - TRANSDUCER CURRENT 50A ETA TECHNOLOGY
Obsolete
Check Stock & Lead Times Packaging Options
LEM DHAB S/134, TRANSDUCER CURRENT 200A HALL EFFECT,OPEN LOOP,AUTO
Obsolete
Check Stock & Lead Times Packaging Options
LEM HASS 100-S, TRANSDUCER CURRENT 100A HALL EFFECT,OPEN LOOP
Obsolete
Check Stock & Lead Times Packaging Options
LEM CASR 25-NP, TRANSDUCER CURRENT 25A FLUX GATE,CLOSED LOOP
Obsolete
Check Stock & Lead Times Packaging Options
LEM LAS 100-TP, TRANSDUCER CURRENT 100A ETA TECHNOLOGY
Obsolete
Check Stock & Lead Times Packaging Options
PHOENIX 2308030, TRANSDUCER CURRENT 0-200A 24VDC
Obsolete
Check Stock & Lead Times Packaging Options
TEG NA100-P, TRANSDUCER CURRENT 100A
Obsolete
Check Stock & Lead Times Packaging Options
LEM HA200SB, TRANSDUCER CURRENT 200A HALL EFFECT,OPEN LOOP
Obsolete
Check Stock & Lead Times Packaging Options
LEM LA 150-TP, TRANSDUCER CURRENT 150A HALL EFFECT,CLOSED LOOP
Obsolete
Check Stock & Lead Times Packaging Options
Showing 1 -